Metabase CVE-2026-72898: how to organise your response
A critical flaw in the Metabase password reset endpoint, CVE-2026-72898, is listed by CISA as exploited. This article explains who is affected and how to organise the response.
PiLabs
PiLabs follows the CISA catalogue and the NVD and publishes summaries.
Latest vulnerabilitiesNews
IK10 and IP66 appear on many security camera data sheets. This guide explains what each rating tests, what it leaves out, and which questions to ask before you buy a camera for outdoor use.
This article was written automatically on 19 November 2026 from the information on this site and checked by automated rules; it was not reviewed by a person. Tell us if something is wrong
A camera data sheet often shows two short codes: IP66 and IK10. They look alike, but they answer different questions. This guide explains what each one means, what it does not promise, and what to check before you buy.
The IP rating (Ingress Protection) says how well the housing keeps out solid objects and water. The IK rating (impact protection) says how much mechanical impact the housing can take before it is damaged.
Both ratings come from laboratory tests with set methods. A camera does not earn a rating by description. It earns it by passing a test. So the first thing to ask is whether the rating applies to the whole camera as sold, or only to one part.
An IP code has two digits. Each digit answers one question.
So IP66 means dust cannot get in and heavy rain or a strong jet of water should not either. For a camera on a wall, a pole or a car park, this is a sensible level.
Two points often cause confusion. First, IP66 does not mean the camera can be put under water. Protection against immersion is a different digit, and a camera can be rated for jets without being rated for immersion. Second, a higher second digit is not always "better" in a simple line. Some codes test different things, so read the digit and its description, not only the size of the number.
The IK scale runs from IK00, which means no protection, to IK10, which is the highest level. Each step matches a stated impact energy, measured in joules. IK10 corresponds to an impact of 20 joules, which is a heavy blow to the housing.
This matters where someone can reach the camera: a corridor, a school yard, a stairwell, a car park, a public building. A camera with a high IK rating is harder to put out of action with a hit from a tool or a thrown object.
Keep in mind what the test measures. It checks that the housing survives a defined impact. It does not promise that the camera will keep its aim, or that it cannot be removed, painted over or covered.
IP66 and IK10 are useful, but they are only part of the picture. They do not tell you about:
A short list helps you compare models without being lost in the numbers.
If the buyer is a public body, it also helps to write the required ratings into the purchase request in plain words. For example, state that the camera must be dust-tight and withstand powerful water jets, and that it must resist a stated level of impact. This keeps offers easy to compare.
Pinet is a supplier of i-PRO products in the Devlet Malzeme Ofisi (DMO) e-catalogue. On the DMO security cameras page, each camera shows its DMO product code and its full technical specification. You can also contact Pinet to choose a camera or to request a quote.
More
A critical flaw in the Metabase password reset endpoint, CVE-2026-72898, is listed by CISA as exploited. This article explains who is affected and how to organise the response.
A firewall that is too small slows the branch down, and one that is too large wastes budget. This guide explains what to measure and what to ask before you choose.
A critical flaw in Kestra OSS lets an unauthenticated attacker run code, and CISA lists it as exploited. This article explains who is affected and how to organise the response.
Write to us. A consultant will answer.