Skip to content
PiLabs security advisory Updated 2 November 2026
High 8.4 CVE-2026-110936 Known exploited

Uncontrolled DLL search path in Siemens Software Center

Affected
Siemens Software Center
Affected versions
< 4.0.9.8
Disclosed
Last updated
CVSS 4.0 vector
AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Written automatically on 27 October 2026 from the NVD and the CISA catalogue of known exploited vulnerabilities. The facts above come from those sources; check them before you act. Updated by Pinet on 2 November 2026. Sources of this advisory

Siemens reports that Siemens Software Center versions before 4.0.9.8 load DLLs from an uncontrolled search path, which could let an authenticated local attacker run code. CISA lists CVE-2026-110936 as exploited.

What is affected

Siemens reports a vulnerability in Siemens Software Center, tracked as CVE-2026-110936. According to the sources, all versions before 4.0.9.8 are affected, which is the range < 4.0.9.8. The weakness is classified as CWE-427, uncontrolled search path element. The sources give 2026-10-15 as the disclosure date.

What the flaw allows

The description from the sources states that the affected application loads dynamic-link libraries (DLLs) from an uncontrolled search path. An authenticated local attacker could place a specially crafted DLL in a directory that the application searches. This could lead to arbitrary code execution with the privileges of the affected application.

The CVSS 4.0 base score is 8.4, which is rated high. The vector describes a local attack with low complexity, no user interaction, high privileges required, and a high impact on confidentiality, integrity and availability of the vulnerable system. The attacker therefore needs an existing account on the host, so the flaw is not described as remotely exploitable.

Exploitation

CISA lists this vulnerability as exploited in its Known Exploited Vulnerabilities catalogue and added it on 2026-10-20. CISA gives 2026-11-03 as its stated deadline for US federal agencies to act. CISA records the use of this vulnerability in ransomware campaigns as unknown. Siemens has also published a news item on active exploitation of CVE-2026-110936, linked below. The sources do not say who is exploiting the flaw or how widely.

What to do

First, find out whether Siemens Software Center is installed on your systems and which version is in use. Compare the version with the affected range < 4.0.9.8. The Siemens advisory describes the vulnerability in detail and lists the fixed releases, so use it as the reference for how to check exposure and which release to move to.

CISA's required action is to apply mitigations in accordance with the vendor's instructions, or to discontinue use of the product if mitigations are not available. Further references are the Siemens security advisory SSA-580366, the Siemens notice on active exploitation, the NVD entry for CVE-2026-110936 and the CISA Known Exploited Vulnerabilities catalogue.

What to do

Follow the vendor instructions in the Siemens security advisory SSA-580366, which lists the fixed releases of Siemens Software Center. CISA's required action is to apply mitigations in accordance with vendor instructions, or to discontinue use of the product if mitigations are unavailable. Check which systems run a version in the range < 4.0.9.8 and prioritise them.

Sources

Mentioned in security bulletins

All vulnerabilities

Need to know whether these vulnerabilities affect you?

A consultant can check which of the affected products you run and what to fix first. For a wider review, ask for a security assessment.